We lend a temporary multi-day sensor kit across south-east Connecticut (starting at $1,850 per job) to measure room evenness, radiator timing, and boiler burn rates—before you spend money, or after a contractor finishes the fix.
Temporary loaner loggers (rooms, far-end radiators/mains, and a shaded outdoor reference cross-checked against a local weather station) measure room-to-room ΔT, arrival timing, and burn-rate splits—comparing before and after strictly across the outdoor temperature range both periods share.
One-visit apps already exist for forced air. For steam, hydronic, and oil-boiler jobs, independent before-and-after measurement helps you differentiate from competitors, close higher-ticket upgrades, and document system output cleanly—priced per job, not per month.
Pre/post verification built for single-family steam and boiler systems where one-visit snapshots miss venting lag, room-to-room drift, and standby burn. Quality assurance is the by-product; winning the next job is the point.
Measured baseline data makes slow mains, cold rooms, or high standby burn obvious so upgrades sell cleanly.
Not a forced-air one-visit app and not an apartment-building control system—built for single-family steam and hydronic homes.
Get a working check while the job is still open so you can dial it in if needed—then both sides receive the full before → adjustment → final log across the shared outdoor temperature range.
Every kit—including the 4-sensor Decision Report—includes one shaded outdoor reference sensor (S4), cross-checked against a nearby weather station. Before and after periods are compared strictly across the outdoor temperature range both runs share.
We report measured radiator/main arrival timing (minutes), room-to-room spread (°F), and boiler burn-rate splits (hot water, standby, and space heating). We never project annual dollar savings from a short multi-day run.
Separating domestic hot-water and standby burn from space heating is cleanest when the boiler runs only for hot water. Winter hot-water share readings carry an explicit seasonal caveat in the report.
Numbered loaner pucks (interior walls at 4 ft, surface probes on far-end mains/radiators, one reference photo per spot, no customer Wi-Fi needed). Every report describes what the data shows—never "you should buy X"—with raw logs attached.
Measure rooms, radiators, and boiler burn rates—then see what the data shows for each option (like a heat-pump water heater, indirect tank, or venting work) before committing to quotes.
Multi-day loaner deployment splits oil-boiler fuel between hot water, standby, and heating, and maps room-to-room ΔT and arrival timing—showing what the data implies for each option without recommending equipment.
Baseline measurement before the job, then the exact same measurement after the work across the outdoor temperature range both periods share. Clear handover proof that wins the next job and reduces guesswork callbacks.
Identical sensor placement pre- and post-work, filtered to the shared outdoor temperature band and scored pass/fail against targets agreed in writing before the job starts.
Seasonal re-measure with the same loaner kit next winter to confirm balance hasn't drifted, with optional leave-behind fuel tracking between visits.
Repeat multi-day verification against your prior baseline to catch slow drift (fouled vents, balance creep, standby rise). Optional leave-behind oil gauge between visits.
Example disclosure: The charts above are an illustrative format example showing how room temperature spread and steam arrival time are reported. When a live before-and-after pilot run is published, its exact dates, shared outdoor temperature band, and measured results will be posted together.
Baseline → Adjustment → Final log.No monthly subscriptions, no permanent hardware to buy, and zero commission on equipment or repairs. We charge a published flat fee per job—written into your 1-page Measurement Plan before anything starts—starting at $1,850. 50% deposit to book.
Need a smaller scope? We narrow the zones measured or start with a single Decision Report run.
I'm Elliot, founder of Clear Difference. Painted-over main vents, lagging radiators, and idle boiler burn never trip an alarm—they just cost fuel and comfort for years. I spent my career as a Navy nuclear-trained officer, where you trust instruments, not opinions. Clear Difference takes zero commission on any equipment or job we report on.
I'm Elliot, founder of Clear Difference. Nothing fails loudly, so nobody notices—slow drift costs fuel and comfort for years. As a former Navy nuclear-trained officer, I was trained in controlled work-package discipline: write down the acceptance criteria before work begins and verify on the gauges after. Clear Difference brings that same independent discipline to single-family steam, hydronic, and oil-boiler homes—zero commission, zero sales.
Proof Through Data · South-east Connecticut (~1 hr drive) · info@cleardifferencedata.com
Answer three quick questions, optionally sketch sensor spots on a floor plan, or email info@cleardifferencedata.com directly.
Answer three quick questions, optionally sketch sensor spots on a floor plan, and pick a callback window.
Opens a pre-filled draft to info@cleardifferencedata.com (plus a Copy Summary fallback). I reply within one business day.
| Metric | How Measured | Pass Target (Agreed in Writing) |
|---|---|---|
| Room-to-room evenness | Placed room loggers across shared outdoor temp band | ≤ 3.5°F spread; rooms inside 68–72°F |
| Heat delivery / arrival timing | Far-end pipe/radiator probes from call start | ≤ 10 min to far end of mains / zones |